TC80 (ÃÑ¿°¼ÒÃøÁ¤±â)
 


 

<< Ư¡ >>

- One-MicrochipÀ» ÀÌ¿ëÇÑ Microprocessor ¹æ½Ä
- Panel Mounted System, Plumb and Play Design
- Amperometric, 3Àü±Ø ¹æ½ÄÀ» ÀÌ¿ëÇÏ¿© Total Chlorine ÃøÁ¤
- 0.005~2.000ppm°ú 0.05~20.00ppmÀÇ ÃøÁ¤¹üÀ§¿¡ ¸Â´Â ¼¾¼­¼±Åð¡´É
- ´Ù¾çÇÑ º¸Á¤¹æ¹ý Á¦°ø
- ÃÑ¿°¼ÒÃøÁ¤°ª, pHÃøÁ¤°ª, ¿Âµµ°ª, °¢Á¾ ¼³Á¤°ª, Set-point »óÅ ǥ½Ã
- ÀÚµ¿ pH °ª º¸»ó, ÀÚµ¿ ¿Âµµº¸»ó
- 2ä³Î T80 ÄÁÆ®·Ñ·¯ Àû¿ë
- 4~20mA 1EA, SPDT Relay 3EA ±âº» Á¦°ø
- ´Ù¾çÇÑ ¿É¼Ç Á¦°ø (¾Æ³¯·Î±× Ãâ·Â 2EA, DC24V Àü¿ø, NEMA 4X ÄÉÀ̽º)


<< »ç¾ç >>

TC ÃøÁ¤ TC ÃøÁ¤¹üÀ§ ¼±Åà 0.005~2.000 ppm(mg/L), 0.05~20.00 ppm(mg/L)
ºÐÇØ´É 0.001 ppm or 0.01 ppm
¿Âµµ ÃøÁ¤ ¿Âµµ ÃøÁ¤ ¹üÀ§ 0 ~ 100¡É
ºÐÇØ´É 0.1 ¡É
Á¦¾î Ãâ·Â - Ãâ·Â ¸±·¹ÀÌ ¼ö : 3°³
- Ãâ·Â ±Ô°Ý : SPDT Á¢Á¡3 (Á¦¾î¿ë)
- ½ºÀ§Äª Àü¾Ð ¹× Àü·ù : AC230VAC/5A
- Ãâ·Â ±â´É : ¾Ë¶÷, ¼¼Á¤, Control (°¢°¢ÀÇ ¸±·¹ÀÌ ¸¶´Ù µ¶¸³ÀûÀ¸·Î ±â´É ¼³Á¤ °¡´É)
- Control ±â´É : On/Off Á¦¾î, ¼¼Á¤ ÀåÄ¡ Á¦¾î
- Alarm ±â´É : High/Low Alarm point, Relay Delay
½ÅÈ£ Ãâ·Â - ¾Æ³¯·Î±× Ãâ·Â ¹üÀ§ : 0/4 ~ 20mA(Àý¿¬) => ¾Æ ³¯·Î±× ½ÅÈ£Ãâ·Â 2°³±îÁö °¡´É (Option)
- ¹ÝÀÀ½Ã°£ : 2.5s for 98%
- Isolation : 250 Vac - Load : 600 ohm max
¼¾¼­ º¸Á¤

- ¼¾¼­ º¸Á¤¹æ¹ý : ¿ë¾×(Á¦·Î, ½ºÆÒ¿ë¾×)À» ÀÌ ¿ë ÇÑ 2Á¡ º¸Á¤

Hold ±â´É - ¼¾¼­ ±³Á¤ ½Ã Auto Hold
- Alarm, Control ¸±·¹ÀÌ : Hold ½Ã°£ ¼³Á¤ °¡´É
- ¾Æ³¯·Î±× Ãâ·Â : Á÷Àü Ãâ·Â °ªÀ¸·Î Hold
»ç¿ë ȯ°æ - ÀÛµ¿ ¿Âµµ : 0/50¡É - ÀÛµ¿ ½Àµµ : ÀÀ°á ¾øÀÌ 95%
±â ±¸ - ÃëºÎ¹æ¹ý : Panel Mounting
- Case ÀçÁú : Polycarbonate
- ¿ÜÇüÄ¡¼ö : 144 x 144 x 190mm (HxWxD)
- ¹«°Ô : 0.75 kg
Àü ¿ø - Àü¿ø°ø±Þ : AC 100~240V, 50/60Hz
- DC 24V (Option)